A close-up of the new chip, equipped with a radio transmitter, which is powered by a natural battery found deep in the mammalian ear. Image: Patrick P. Mercier

Deep in the inner ear of mammals is a natural battery - a chamber filled with ions that produces an electrical potential to drive neural signals. In the latest issue of the journal Nature Biotechnology, a team of researchers from MIT, the Massachusetts Eye and Ear Infirmary (MEEI) and the Harvard-MIT Division of Health Sciences and Technology (HST) demonstrate for the first time that this battery could power implantable electronic devices without impairing hearing.

The devices could monitor biological activity in the ears of people with hearing or balance impairments, or responses to therapies. Eventually, they might even deliver therapies themselves.

In experiments, Konstantina Stankovic, an otologic surgeon at MEEI, and HST graduate student Andrew Lysaght implanted electrodes in the biological batteries in guinea pigs' ears.

Attached to the electrodes were low-power electronic devices developed by MIT's Microsystems Technology Laboratories (MTL). After the implantation, the guinea pigs responded normally to hearing tests, and the devices were able to wirelessly transmit data about the chemical conditions of the ear to an external receiver.

"In the past, people have thought that the space where the high potential is located is inaccessible for implantable devices, because potentially it's very dangerous if you encroach on it," Stankovic says. "We have known for 60 years that this battery exists and that it's really important for normal hearing, but nobody has attempted to use this battery to power useful electronics."

The ear converts a mechanical force - the vibration of the eardrum - into an electrochemical signal that can be processed by the brain; the biological battery is the source of that signal's current.

Located in the part of the ear called the cochlea, the battery chamber is divided by a membrane, some of whose cells are specialized to pump ions. An imbalance of potassium and sodium ions on opposite sides of the membrane, together with the particular arrangement of the pumps, creates an electrical voltage.

Although the voltage is the highest in the body (outside of individual cells, at least), it's still very low. Moreover, in order not to disrupt hearing, a device powered by the biological battery can harvest only a small fraction of its power. Low-power chips, however, are precisely the area of expertise of Anantha Chandrakasan's group at MTL.

The MTL researchers - Chandrakasan, who heads MIT's Department of Electrical Engineering and Computer Science; his former graduate student Patrick Mercier, who's now an assistant professor at the University of California at San Diego; and Saurav Bandyopadhyay, a graduate student in Chandrakasan's group - equipped their chip with an ultralow-power radio transmitter: After all, an implantable medical monitor wouldn't be much use if there were no way to retrieve its measurements.

But while the radio is much more efficient than those found in cellphones, it still couldn't run directly on the biological battery. So the MTL chip also includes power-conversion circuitry - like that in the boxy converters at the ends of many electronic devices' power cables - that gradually builds up charge in a capacitor.

The voltage of the biological battery fluctuates, but it would take the control circuit somewhere between 40 seconds and four minutes to amass enough charge to power the radio. The frequency of the signal was thus itself an indication of the electrochemical properties of the inner ear.

To reduce its power consumption, the control circuit had to be drastically simplified, but like the radio, it still required a higher voltage than the biological battery could provide. Once the control circuit was up and running, it could drive itself; the problem was getting it up and running.

The MTL researchers solve that problem with a one-time burst of radio waves. "In the very beginning, we need to kick-start it," Chandrakasan says. "Once we do that, we can be self-sustaining. The control runs off the output."

Stankovic, who still maintains an affiliation with HST, and Lysaght implanted electrodes attached to the MTL chip on both sides of the membrane in the biological battery of each guinea pig's ear. In the experiments, the chip itself remained outside the guinea pig's body, but it's small enough to nestle in the cavity of the middle ear.

Cliff Megerian, chairman of the otolaryngology department at Case Western Reserve University, says that he sees three possible applications of the researchers' work: in cochlear implants, diagnostics and implantable hearing aids.

"The fact that you can generate the power for a low voltage from the cochlea itself raises the possibility of using that as a power source to drive a cochlear implant," Megerian says. "Imagine if we were able to measure that voltage in various disease states. There would potentially be a diagnostic algorithm for aberrations in that electrical output."

"I'm not ready to say that the present iteration of this technology is ready," Megerian cautions. But he adds that, "If we could tap into the natural power source of the cochlea, it could potentially be a driver behind the amplification technology of the future."

The work was funded in part by the Focus Center Research Program, the National Institute on Deafness and Other Communication Disorders, and the Bertarelli Foundation.

.


Related Links
MIT
Hospital and Medical News at InternDaily.com






Comment on this article via your Facebook, Yahoo, AOL, Hotmail login.

Share this article via these popular social media networks
del.icio.usdel.icio.us DiggDigg RedditReddit GoogleGoogle








INTERN DAILY
New micropumps for hand-held medical labs produce pressures 500 times higher than car tire
Washington DC (SPX) Nov 16, 2012
In an advance toward analyzing blood and urine instantly at a patient's bedside instead of waiting for results from a central laboratory, scientists are reporting development of a new micropump capable of producing pressures almost 500 times higher than the pressure in a car tire. Described in ACS' journal Analytical Chemistry, the pumps are for futuristic "labs-on-a-chip," which reduce entire l ... read more


INTERN DAILY
New Israeli anti-missile system gets ready

Israel's Iron Dome plays growing role in Gaza conflict

Lockheed Martin Continues To Supporting US Air Defense, Missile Warning and Space Defense Missions

US, Israel wrap up major joint missile drill

INTERN DAILY
N. Korea shipped missile parts to Syria: media

Patriot Air and Missile Defense System receives US Army stamp of approval

India to buy Russia's Konkurs-M, Invar guided missiles

Taiwan tests new anti-ship missile: report

INTERN DAILY
Israel destroys Gaza drone workshop: army

Iran minister confirms firing at US drone in Gulf

Iranian jets fired on US drone in Gulf: Pentagon

Sagetech, Arcturus Demonstrate Joint Manned, Unmanned Aircraft Operations using COTS NextGen ADS-B Tracking

INTERN DAILY
The Skynet 5D secure telecom satellite is received in French Guiana for Arianespace's December Ariane 5 mission

Lockheed Martin Completes On Orbit Testing of Second AEHF Satellite

LynuxWorks LynxOS-SE Deployed by ITT Exelis in New Line of Software-Defined Radios

Digital Modular Radios For New US Navy Ships and Submarines

INTERN DAILY
Stone-tipped weapons older than thought

Australia rolls out Thales desktop system

Northrop Grumman Begins Full-Rate Production of LITENING SE Targeting Pods for USAF

Northrop Grumman and ITT Exelis Partner for U.S. Navy's Next Generation Jammer

INTERN DAILY
Panetta orders ethics review for US top brass

US defence chief in Thailand to boost military ties

Cameron defends Gulf trip

Have America's generals lost their way?

INTERN DAILY
Xi raises hopes, but China's reform outlook cloudy

Jealous lover and bad luck brought down CIA chief

China top censor's new leadership role raises fears

ASEAN calls for South China Sea hotline

INTERN DAILY
Pull with caution

What if the nanoworld slides

Strain tuning reveals promise in nanoscale manufacturing

Low-resistance connections facilitate multi-walled carbon nanotubes for interconnects




The content herein, unless otherwise known to be public domain, are Copyright 1995-2014 - Space Media Network. AFP, UPI and IANS news wire stories are copyright Agence France-Presse, United Press International and Indo-Asia News Service. ESA Portal Reports are copyright European Space Agency. All NASA sourced material is public domain. Additional copyrights may apply in whole or part to other bona fide parties. Advertising does not imply endorsement,agreement or approval of any opinions, statements or information provided by Space Media Network on any Web page published or hosted by Space Media Network. Privacy Statement