For more than a decade, the National Institute of Standards and Technology (NIST) has been unveiling experimental next-generation atomic clocks. These clocks, based on ytterbium, strontium, aluminum, and mercury atoms, among others, have set records for precision and stability.

But, so what? It's all part of NIST's continual effort to improve its ability to maintain and disseminate official U.S. civilian time. A practical question has been when such experimental clocks could begin to be used to support official timekeeping.

New NIST simulations suggest these clocks may now be reliable and practical enough to start contributing to calibrations that support official U.S. civilian time.

Currently, cesium fountain clocks NIST-F1 and NIST-F2 are operated for about one week each month to calibrate NIST time scales , arrays of hydrogen masers - microwave versions of lasers - maintaining official U.S. civilian time for distribution to financial markets and millions of other users around the world. Without such calibrations, official time drifts a bit.

Next-generation clocks operate at optical frequencies, much higher than the microwave frequencies of cesium clocks. Optical clocks are complex physics laboratory setups and typically run only intermittently.

"In principle, the optical clock should be the best frequency reference in the building," said Chris Oates, chief of NIST's Time and Frequency Division. "These clocks are getting more reliable, more robust all the time. There have been experiments where they run these things for days."

"We wanted to answer the question, 'Is it worth it right now spending some effort in trying to compare our existing optical clocks to the time scale?' This paper confirmed that it makes sense to perform a first evaluation."

Indeed, similar first demonstrations are underway at other National Metrological Institutes around the world. In such demonstrations, optical clocks are not generating or keeping official time - rather, they provide extremely stable (intermittent) frequency references that support time generation.

The NIST simulations found that to achieve the same performance as a cesium-fountain-calibrated time scale, NIST would need to run an optical clock for 12 minutes every 12 hours, or 1 hour per day, or 4 hours every 2 and 1/3 days, or 12 hours per week. Among other benefits, such calibrations could reduce the error in official time to just 2 nanoseconds (ns), better than current offsets in NIST official time.

Because any timing error gets progressively worse, the study suggests running an optical clock 4 hours at a time at least 3 times a week.

NIST is already using optical clocks to monitor masers in the time scale. The plan now is to build a system to use optical clock results to create a "paper time scale" and accumulate data on how it compares to the real thing. In principle, any time and frequency input can be used to calibrate the time scale; more accurate inputs are given more weight. The expectation is that optical clocks will prove useful for real calibrations even with their modest availability, as they could provide good support while running less often than cesium clocks.

To make the process easier, NIST could operate multiple optical clocks and switch between them for calibration purposes. By running different optical clocks in different time slots, NIST could distribute the workload to different labs and staff.

The NIST simulation study found that various types of optical clocks could be used to calibrate the time scale. That's because most of these clocks have higher stability and lower uncertainty than the time scale, so any uncertainty in estimates of the frequency sources that support official time would be due mainly to the stability limitations of the time scale. Further, NIST official time cannot be more accurate than international standards, so for now there is no pressing need to improve on the time scale.

That could soon change, however. These studies may be helpful in a future redefinition of the International System of Units (SI). The standard unit of time, the second, has been based on properties of the cesium atom since 1967. In the coming years, the international scientific community is expected to redefine the second, selecting a new atom as the basis for standard atomic clocks and official timekeeping.

J. Yao, T. Parker, N. Ashby and J. Levine. 2017. Incorporating an Optical Clock into a Time Scale. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. Posted online Nov. 14 as Early Access. DOI: 10.1109/TUFFC.2017.2773530

TIME AND SPACE
A bit of a 'quantum magic trick'
St. Louis MO (SPX) Nov 06, 2017
An accurate analog clock tick-tick-ticks with a constant precision and well known frequency: one tick per second. The longer you let it tick, the better to test its accuracy --10 times as long corresponds to a ten-fold improvement in any frequency uncertainty. But is there a faster way to determine a frequency? It turns out there is, in a new discovery published this week in Physical Revie ... read more

Related Links
National Institute of Standards and Technology
Understanding Time and Space


Thanks for being here;
We need your help. The Space Media Network continues to grow but revenues have never been harder to maintain.

With the rise of Ad Blockers, and Facebook - our traditional revenue sources via quality network advertising continues to decline. And unlike so many other news sites, we don't have a paywall - with those annoying usernames and passwords.

Our news coverage takes time and effort to publish 365 days a year.

If you find our news sites informative and useful then please consider becoming a regular supporter or for now make a one off contribution.
SpaceMediaNetwork Contributor
$5 Billed Once


credit card or paypal
SpaceMediaNetwork Monthly Supporter
$5 Billed Monthly


paypal only


Comment using your Disqus, Facebook, Google or Twitter login.

Share this article via these popular social media networks
del.icio.usdel.icio.us DiggDigg RedditReddit GoogleGoogle

TIME AND SPACE
Russia test-fires new interceptor missile

US Scrambles to Assemble Space-Based Missile Defense System

Boeing meets 2017 ballistic missile defense installation goal early

Sweden picks US Patriot missile system over European rival

TIME AND SPACE
State Dept. approves potential Javelin missile sale to Georgia

State Dept. approves potential missile sale to Poland

Raytheon awarded contract for Evolved Sea Sparrow Missile program

Lockheed Martin to test AGM-158 JASSM

TIME AND SPACE
Drone Race: Human Versus Artificial Intelligence

Pentagon steps up Somalia drone strikes

Lockheed Martin Integrates New Engine for Fury Unmanned Air Vehicle

Alpha Unmanned Systems teams with Sightec for image stabilization and object tracking.

TIME AND SPACE
US Navy accepts 5th MUOS Satellite for global military cellular network

SES GS Awarded US Government Satellite Solutions Contract

16th SPCS Defenders of critical satellite communications

First order for Elta ELK-1882T SATCOM network system

TIME AND SPACE
Marines roll out new anti-tank weapon system

Saab to supply South African forces with field kitchens

Raytheon, Saab to develop improved shoulder-launched weapon systems

MBDA Inc. to produce parts for Small Diameter Bomb

TIME AND SPACE
Greek government faces questions over botched Saudi arms sale

Congress sends $700 bn defense bill for Trump's signature

Lockheed, Navantia renew collaborative agreement

Philippines' Duterte receives Russian assault rifles

TIME AND SPACE
Australia calls for US engagement in region amid China rise

From Myanmar to Zimbabwe, China's global footprint grows

China forges 'strategic' ties with Djibouti after opening base

Forbidden City and Vatican try 'art diplomacy'

TIME AND SPACE
Ceria nanoparticles: It is the surface that matters

Semiconducting carbon nanotubes can reduce noise in interconnects

Manganese dioxide shows potential in micromotors

Promising sensors for submarines, mines and spacecraft









The content herein, unless otherwise known to be public domain, are Copyright 1995-2024 - Space Media Network. All websites are published in Australia and are solely subject to Australian law and governed by Fair Use principals for news reporting and research purposes. AFP, UPI and IANS news wire stories are copyright Agence France-Presse, United Press International and Indo-Asia News Service. ESA news reports are copyright European Space Agency. All NASA sourced material is public domain. Additional copyrights may apply in whole or part to other bona fide parties. All articles labeled "by Staff Writers" include reports supplied to Space Media Network by industry news wires, PR agencies, corporate press officers and the like. Such articles are individually curated and edited by Space Media Network staff on the basis of the report's information value to our industry and professional readership. Advertising does not imply endorsement, agreement or approval of any opinions, statements or information provided by Space Media Network on any Web page published or hosted by Space Media Network. General Data Protection Regulation (GDPR) Statement Our advertisers use various cookies and the like to deliver the best ad banner available at one time. All network advertising suppliers have GDPR policies (Legitimate Interest) that conform with EU regulations for data collection. By using our websites you consent to cookie based advertising. If you do not agree with this then you must stop using the websites from May 25, 2018. Privacy Statement. Additional information can be found here at About Us.